PERSONAL
PROTECTIVE EQUIPMENT |
|
The personal protective
equipment available from Indian Springs Specialty Products is designed specifically for
the chlorine and HAZMAT responder. Chlorine (HAZMAT) response typically calls for the
highest level of protection (Level A) for your personnel. The Responder and Vanguard are
the reliable and economical choices.
|
|
RESPONDER |
 |
- The Responder is a lightweight level 'A'
total encapsulating suit designed and priced to be a limited use garment. The suit is
durable enough to withstand several uses, while also being economical enough to discard
when contaminated or when the suit shows signs of wear. (Suit #41550
pictured)
- Excellent protection to a wide variety of
chemicals including chlorine, sulfur dioxide and ammonia (chemical compatibility chart
available)
- Tough but lightweight substrate and composite
material
- Seams are sewn and heat sealed
- Expanded polished PVC window
- Two covered exhalation valves
- Taper shape with roomy sleeves and internal
waist belt
- Attached butyl gloves, sock boots and splash
guards
|
|

|
Styles
& Pricing
| Responder Decontamination
Shower The Responder
Decontamination Shower greatly reduces the possibility of environmental contamination with
the chemical resistance of Responder film laminate material as the catch basin for
decontamination run-off. Shower Features:
- Lightweight construction and easy assembly
- Compact storage and carry bag
- Removable spray wand with adjustable water
flow control
- Resistant to a broad range of chemicals (170
chemicals tested)
Note: Responder is a
registered trademark of Kappler (Shower #D7000 pictured)
|
 |
Home
Kits PPE
HazMat Training
Price Catalog
Feedback
|
|
|
The Frontier is
a compressed air, self-contained breathing apparatus which
is NIOSH/MSHA approved and designed for non-firefighting
emergency response and HAZMAT applications. The Frontier
offers total respiratory protection for hazardous
environments, including those deemed Immediately Hazardous
to Life and Health (IDLH). Frontier is available with.
NOT FOR
FIREFIGHTING.
Features:
Compact
demand valve (CDV) is ISI’s newest high flow regulator
that’s the smallest on the market. A first breath option
available. NIOSH approved.
-
High
performance, low breathing rate
-
Silicone
face mask
-
face mask
mounted demand valve
-
Wide-ranging
adaptability
-
Proven
Performance
-
NOT NFPA
approved
-
3 year
Warranty
SCBA STYLES & OPTIONS
|
| |
|

A single curve, 4-point spider harness and is available in
two sizes. Utilizes the CDV regulator. |
|

Allows users with
facial hair or glasses to enter an IDLH atmosphere. Utilizes
the CDV regulator. |
| |
|
Home
Kits PPE
HazMat Training
Price Catalog
Feedback
|
The Vanguard is an open-circuit, compressed air,
self-contained breathing apparatus which is NIOSH/MSHA
approved and designed for non-firefighting emergency
response and HAZMAT applications. (Vanguard 30 SCBA, #VLA3
pictured)The Vanguard offers total respiratory protection
for hazardous environments, including those deemed
Immediately Hazardous to Life and Health (IDLH).
Not
for Firefighting.
Features:
-
High
performance, low breathing rate
-
Silicone
face mask
-
face mask
mounted demand valve
-
Wide-ranging
adaptability
-
Proven
Performance
-
NOT NFPA
approved see Magnum
Shipping: UPS direct from factory or our location
without air due to HazMat restrictions
|
SCBA STYLES & OPTIONS
Accessories
SCBA Wall Cases by ENCON #VWCY - Critical
breathing air equipment requires superior protection from hostile environments to insure
proper operation when you need it most. Protect your breathing apparatus, protective
clothing and accessories in the field-proven wall case. wall case # VWCY is designed
with an universal bracket to fit a wide variety of SCBA including the
Frontier.
Features:
- Chemical resistant/durable ABS plastic
- Rugged design and secure closure
- convenient sizes
- Tamper seal
A wide variety of cabinets are also available for
storage of protective clothing, special tools et. Please "click" on the feedback
form icon to request further product information and pricing. |
 |
Home
Kits PPE
HazMat Training
Price Catalog
Feedback
|
Emergency
Escape Breathing Apparatus (EEBA) |
 |
EEBA
- Emergency
Escape Breathing Apparatus - 40 LPM Constant
Flow Rate |
|
The ISI EEBA provides
respiratory protection for escape from atmospheres
that have suddenly become Immediately Dangerous to
Life or Health (IDLH). The unit is totally
self-contained inside the bright carrying pouch
which can be stored in work areas or carried around
the waist, around the neck, or over the shoulder.
Should an environment
become IDLH, the user would simply remove the hood
from the pouch, turn the cylinder valve on, don the
hood and escape. It is that simple and quick!
Unit is constant flow not "on-demand".
With your choice of
clear Polyurethane hoods for cold areas or clear PVC
hoods for warm weather areas there are no
adjustments to make. The hood allows full peripheral
vision even with long hair, facial hair or glasses.
The ISI EEBA is available
in two versions:
(Items ship
direct from ISI with Air, add $45.00 Hazmat chg. to
Freight total)
|
Model |
Escape Time |
Flow
Rate |
Size |
|
ISI 5 |
5
minutes |
36 - 39 lpm |
14" L X 5" W
X 7"H - 13 LBS. |
|
ISI 10 |
10 minutes |
36 - 39 lpm |
19" L X 5" W
X 7" H - 13 LBS. |
|
Part# |
Part# |
Pneumatics |
| |
G1 |
5 Min.
Escape |
| |
G2 |
10 Min.
Escape |
| |
|
|
| |
01 |
Polyvinylchloride (PVC) Hood |
| |
02 |
Polyurethane
(PU) Hood |
| |
|
|
| |
A |
None |
| |
B |
Carrying
Case |
|
Home
Kits PPE
HazMat Training
Price Catalog
Feedback
|
 |
CEEBA
- Emergency Escape
Breathing Apparatus - Air On Demand Flow Rate |
| The
ISI CEEBA provides respiratory protection for escape from
atmospheres that have suddenly become Immediately Dangerous
to Life or Health (IDLH). The unit is totally self-contained
inside the bright carrying pouch which can be stored in work
areas or carried around the waist, around the neck, or over
the shoulder.
Should an environment become
IDLH, the user would simply remove the hood from the pouch,
turn the cylinder valve on, don the hood and escape. It is
that simple and quick! Unit is constant flow not
"on-demand".
With your choice of clear
Polyurethane hoods for cold areas or clear PVC hoods for
warm weather areas there are no adjustments to make. The
hood allows full peripheral vision even with long hair,
facial hair or glasses.
The ISI CEEBA is available in two
versions:
(Items
ship direct from ISI with Air, add $45.00 Hazmat chg. to
Freight total)
|
Model |
Escape Time |
Flow Rate |
Size |
|
ISI 5 |
5 minutes |
36 - 39 lpm |
14" L X 5" W X 7"H -
13 LBS. |
|
ISI 10 |
10 minutes |
36 - 39 lpm |
19" L X 5" W X 7" H
- 13 LBS. |
|
Part# |
Part# |
Pneumatics |
| |
CE1 |
5
Min. Escape |
| |
CE2 |
10
Min. Escape |
| |
|
|
| |
01 |
Polyvinylchloride (PVC) Hood - SM (M/LG - 02) |
| |
03 |
Polyurethane (PU)
Hood - SM (M/LG - 04) |
| |
|
|
| |
A |
None |
| |
B |
Carrying Case |
|
|
|